The CER Directive: requirements and implementation in Poland

What the CER Directive means for operators in Poland: who becomes a critical entity, what duties and deadlines follow, the fines, how CER ties in with NIS2 and where drones belong in the risk assessment.

Updated:

In short. Poland implemented the CER Directive through an act that amended the Crisis Management Act and has applied since 4 July 2026. Only an operator of critical infrastructure can become a critical entity. The authorities must make the first entries on the list of critical entities by April 2027. From notice of entry, the clocks run: 30 days for a security officer, 9 months for a risk assessment, then 3 months to put measures in place. Every critical entity is also an essential entity under the Polish rules implementing NIS2.

This guide covers Polish law. Polish statute titles are given in English translation; the sources list links to the official texts.

What the CER Directive is

Directive (EU) 2022/2557 of the European Parliament and of the Council concerns the resilience of critical entities: companies and institutions that provide services essential to society and the economy. It replaced Directive 2008/114/EC, repealed with effect from 18 October 2024 (art. 27). Member states had to transpose CER by 17 October 2024 (art. 26(1)).

It covers 11 sectors: energy, transport, banking, financial market infrastructure, health, drinking water, waste water, digital infrastructure, public administration, space, and the production, processing and distribution of food (Annex).

How Poland implemented CER

Through the Act of 29 May 2026 amending the Crisis Management Act and certain other acts (Dz.U. 2026 item 815), published on 19 June 2026. It took effect 14 days later, on 4 July 2026 (art. 73), about 20 months after the EU deadline.

The new rules sit in the Crisis Management Act. Its latest consolidated text (Dz.U. 2026 item 574) doesn’t yet include them, so it has to be read together with the amending act.

Who becomes a critical entity

In Poland it works in two steps.

  1. The list of critical infrastructure. Kept by the director of the Government Centre for Security (RCB) (art. 6r(1)) and classified (art. 6r(3)). Whoever has a facility, device, installation, network, system or service entered on it is an operator of critical infrastructure (art. 3(3a)).
  2. The list of critical entities. Also kept by the RCB director (art. 6zo(1)). A critical entity is an operator of critical infrastructure entered on this list (art. 3(1a)).

An operator goes on the list of critical entities when it meets four conditions at once (art. 6zp(1)): it works in a sector or subsector listed in the act’s annex, provides at least one essential service, has critical infrastructure in Poland, and an incident would significantly disrupt that service.

The entry is requested by the authority for the sector, for example the energy minister (electricity and heat), the transport minister, or the Financial Supervision Authority (KNF) for banks (art. 6zk(1) and art. 6zl(3)). The operator is informed of the entry within 30 days at the latest (art. 6zr(3)).

The authorities must identify the first critical entities and enter them on the list within 9 months of the act taking effect, that is by April 2027 (art. 34 of the amending act). The directive set 17 July 2026 for this (art. 6(1)).

To see whether this applies to your company, use our CER check. It asks five questions and, if you have already been entered, works out your deadlines.

Duties of a critical entity

Deadlines run from the day the entity is informed of its entry on the list.

Duty Deadline Crisis Management Act
Essential-service security officer (pełnomocnik bezpieczeństwa usługi kluczowej) and a deputy 30 days art. 6zzd(2)
Risk assessment 9 months (banking and financial market infrastructure: 10), then at least every 2 years art. 6zt(1)(1) and (3), art. 6zze
Organisational and technical measures, including physical protection of buildings and grounds 3 months after the risk assessment art. 6zt(1)(2) and (4)
Documentation of the integrated security management system for the essential service 15 months art. 6zu(4)
Audit at least every 3 years, at the entity’s own cost art. 6zz(1)
Register of critical suppliers and their risk assessment at least once a year art. 6zzo

Poland is stricter than the directive here. CER requires a risk assessment at least every four years (art. 12(1)); the Polish act requires one every two.

Incidents. A significant incident, one that causes or may cause a significant drop in the quality of an essential service or an interruption to it, and meets the thresholds set by regulation (art. 3(1g), art. 6zv(4)), must be reported without delay and within 24 hours of its occurrence or detection. The report goes to the sector authority and the RCB director, the Head of the Internal Security Agency (ABW) and the national CSIRT (art. 6zv(1)(4)). Within 30 days of the incident, the entity sends the sector authority and the RCB director a report on how it handled the incident (art. 6zv(1)(7)).

Background checks. The entity may check the background of staff and candidates in sensitive roles, of anyone (including contractors) with direct or remote access to its buildings, grounds, information flows or control systems, and of auditors, including criminal records. Checks are repeated at least every 3 years (art. 6zzc). This is a right, not a duty.

Fines

Fines are imposed by decision of the sector authority (art. 6zzs(1)). Depending on the breach, they range from PLN 2,000 to PLN 200,000 (art. 6zzr(2) and (3)), for example:

  • no risk assessment: PLN 15,000 to 100,000,
  • security measures not implemented: PLN 15,000 to 150,000,
  • an incident not reported: PLN 2,000 to 25,000 per case,
  • no audit: PLN 15,000 to 200,000,
  • no security officer: PLN 2,000 to 15,000.

CER and NIS2

NIS2 (Directive (EU) 2022/2555) is about cybersecurity; CER about physical and organisational resilience. Poland implemented NIS2 through the Act of 23 January 2026 amending the National Cybersecurity System Act and certain other acts (Dz.U. 2026 item 252), published on 2 March 2026 and in force since April 2026.

One rule ties the two together: every critical entity is an essential entity under the National Cybersecurity System Act, whatever its size (art. 5(1)(4)(c) of that act). It therefore has duties under both acts. Cybersecurity breaches are fined by the cybersecurity authority, and the same act is not pursued in two proceedings (art. 6zzt of the Crisis Management Act).

Two sectors are treated differently. Chapters 11–15 of the Crisis Management Act don’t apply to critical entities in digital infrastructure (art. 6zzx), whose security is governed mainly by NIS2. Chapters 11–15 also don’t apply to banking and financial market infrastructure, with exceptions: they must still, among other things, carry out the risk assessment, put physical protection in place and appoint a security officer (art. 6zzw). Art. 8 of the CER Directive exempts all three sectors alike but lets member states require more, which Poland did for banks.

Drones in the risk assessment

The CER Directive doesn’t mention drones. It does require adequate physical protection of premises and critical infrastructure, taking account of, for example, fencing, barriers, perimeter monitoring tools and routines, and detection equipment and access controls (art. 13(1)(b)).

The Polish act requires the risk assessment to cover antagonistic threats too, meaning deliberate hybrid threats against essential services (art. 6zt(1)(1)(a), art. 3(22)), and the measures to include physical protection of buildings and grounds (art. 6zt(1)(2)(b)). In our view, a drone over a power plant, substation or water intake falls under both.

The European Commission wrote in its communication on countering potential threats posed by drones of 18 October 2023 (COM(2023) 659) that countering drone threats should be included in future risk assessments under the CER Directive. The communication also notes that private operators of critical infrastructure often lack the legal authority to neutralise drones.

In Poland that has partly changed. Since 4 July 2026, an operator of critical infrastructure may decide to allow a jammer while specialist armed security guards (SUFO) are acting, in the cases under art. 156ze(1) of the Aviation Law and two other acts. It must first notify the interior minister, the President of UKE and the military frequency authority of the possible use and the device parameters, and tell them promptly after any use (art. 6zj of the Crisis Management Act). Ordinary security staff have no such power. More in our guide A drone over your site: what to do and what not to do.

A drone risk assessment built on facts rather than guesses needs data: how many drones fly over the site, when, how close and where they take off from. A detection record provides it. HARQ sensors receive Remote ID and record every flight in an archive you can export and attach to the risk assessment.

What to do now

If your company operates critical infrastructure or expects to be entered on the list:

  1. Work out which of your services could count as essential, and which sector you’re in.
  2. Pick a candidate for essential-service security officer. After entry you’ll have 30 days.
  3. Start collecting data for the risk assessment, including on antagonistic threats such as drones over the site.
  4. Set up your incident reporting path: 24 hours isn’t long when nobody knows who calls whom.
  5. Check your duties under the National Cybersecurity System Act. Once entered on the list of critical entities, you’ll also be an essential entity.

The details, such as the list of essential services, the thresholds for significant incidents and the list of standards for information security, business continuity and physical protection, will be set by Council of Ministers regulations (art. 6zp(3), art. 6zv(4), art. 6zt(5)). As of 23 October 2026 we couldn’t find them in ISAP.

Sources

The law as of 23 October 2026. We checked the Polish provisions in ISAP, in the current consolidated texts and the published amending acts.

This guide is for information only and is not legal advice. For a specific case, consult a lawyer.